UL Listed and FM Approved products · ISO 9001:2015 · IS / IEC Standards. From a single cable to a complete fire suppression system, engineered & tested in-house.
NEW grooved pipe joints for fire protection lines.
A grooved joint connects steel pipe without welding: a gasket and a two-bolt housing lock into grooves cut on the pipe ends. DPCL supplies the NEW range of grooved couplings, fittings and branch outlets, with site support.
Styles 1GS, 1X, 1F and 1GH. Hold the pipe straight and firm. DN25 to DN300.
Styles 1N, 1NH and reducing 1NR. Take pipe movement and vibration. DN25 to DN300.
Style 321 split flange and Style 321G flange adapter for valves, pumps and flanged equipment.
90°, 45°, 22.5° and 11.25° elbows, equal and reducing tees and crosses. DN25 to DN300.
Concentric and eccentric reducers, end caps and grooved nipples.
Branch outlets without welding: Style 3G, 3J, 3JS and 3L tees, and 4G and 4J crosses.
| Housing | Ductile cast iron, ASTM A-536 Grade 65-45-12 |
| Finish | Red epoxy coated; hot dip galvanized on request |
| Gasket | EPDM standard; nitrile, silicone, others on request |
| Working Pressure | 300 PSI (20.65 bar), standard styles |
| Sizes | DN25 to DN300; larger couplings on enquiry |
| Approvals | Maker's FM and UL certificates; listed styles up to DN300 |
Electric & diesel fire pump sets from certified manufacturers, for NFPA 20 systems.
DPCL supplies NAFFCO fire pump packages, UL Listed or FM Approved for the listed models, jockey pumps through full triplex sets (electric main + diesel standby + jockey), with system design, installation, and NFPA 20 documentation included.
UL/FM listed horizontal split-case, vertical turbine or end-suction pumps with electric motor drive.
FM/UL listed diesel-driven standby pumps with automatic start on pressure drop, meeting NFPA 20 standby requirements.
Small-capacity pumps to maintain system pressure and detect minor leaks without activating the main pump.
NFPA 20 compliant electric & diesel pump controllers with auto/manual start, fault alarms and test facilities.
Complete pump room design: pumps, valves, pipework, suction tank, instrumentation and controller, all from a single source.
| Flow Range | 100 LPM to 10,000 LPM |
| Head | Up to 150 m |
| Certifications | UL 448 / FM 1319 / NFPA 20 |
| OEM Brands | Pumpsense, NAFFCO |
| Power Supply | 415V 3Ph / Diesel standby |
| Testing | Factory flow test certificate supplied |
NBC 2016 and NFPA based wet, dry and deluge systems for all occupancy types.
DPCL designs, supplies and installs complete fire hydrant and automatic sprinkler systems to NBC 2016 and NFPA standards. Our scope includes hydraulic design, pipe network, valves, pumps, heads and commissioning. We also supply and install high-pressure water mist systems for turbine halls, server rooms and marine applications.
High-pressure hydrant networks for industrial and commercial sites, sized to NBC and NFPA flow requirements.
Automatic sprinkler systems with thermal-activated heads, designed to NFPA 13 coverage patterns.
Wall-mounted and recessed hose reel cabinets in corrosion-resistant materials, per IS:884.
AFFF and AR-AFFF foam systems for fuel storage, aircraft hangars and petrochemical plants.
Open-head sprinkler systems with dedicated deluge valve for transformer rooms, cable tunnels and high-hazard areas.
| Design Standard | NBC 2016 Part IV and the applicable NFPA standard for each system |
| Pipe Material | GI (IS:1239) / CS (ASTM A795) / CPVC |
| Head Types | Pendant, Upright, Sidewall, ESFR |
| Products Range | Hydrants, Hose Reel Box, Hose Reel, Sprinklers, vaults |
| Brands | Armorfire |
| Testing | Hydrostatic test + flow test at commissioning |
Clean agent & CO₂ systems protecting server rooms, archives and clean rooms.
DPCL designs, supplies and commissions total flooding gas suppression systems for spaces where water-based suppression would cause secondary damage. We work with FM200 (HFC-227ea), Novec 1230, Inergen (IG-541) and CO₂ systems, fully compliant with NFPA 2001 and IS:15493.
Most widely used clean agent. Zero ozone depletion, low residue, safe for occupied spaces. Ideal for server rooms, UPS rooms, control rooms.
Clean agent with a low global warming potential. Zero collateral damage, occupant-safe. Supply of this agent depends on current availability, so confirm before specifying.
Inert gas blend (N₂, Ar, CO₂) with zero environmental impact. Preferred for telecom exchanges and archival storage.
Total flooding CO₂ for unoccupied spaces: generator enclosures, cable tunnels, industrial process equipment.
Addressable or conventional detection with pre-discharge alarm, abort switch, solenoid valve control and monitoring.
| Coverage | Single zone to multi-zone sequential |
| Agents | FM200, Novec 1230, Inergen, CO₂ |
| Standards | NFPA 2001 / IS:15493 / ISO 14520 |
| Applications | Server rooms, UPS, Archives, Control rooms |
| Detection | VESDA / addressable / conventional |
| Cylinder Range | 5 kg to 200 kg per cylinder |
High-Quality LT Panel Manufacturing by Druthi Power Controls (DPCL)
We manufacture LT electrical panels for Commercial Buildings, IT & ITES, Infrastructure Projects, Metro Rail Projects, Industry, and Pharmaceuticals. Established in 2021, and backed by directors with over 40 years of combined corporate experience.
For electrical enclosures, VFDs, and switchgear, our technology partners are Siemens, ABB, and Schneider Electric.
We manufacture robust Motor Control Centre (MCC) panels designed for centralized and safe control of heavy-duty industrial and utility motor loads.
Scalable and reliable power distribution hubs. We supply sub main and consumer distribution panels engineered to manage and distribute electrical loads safely across commercial complexes, manufacturing units, and healthcare facilities.
Smart energy management and precise speed control for dynamic loads. We manufacture VFD panels for pump and motor applications, partnering with trusted global OEMs like Siemens, ABB, and Schneider Electric for our VFDs and electrical switchgear.
Mission-critical reliability when lives are on the line. We provide dedicated electrical control panels engineered specifically for fire pump systems to ensure an immediate response during emergencies.
Advanced building and industrial automation solutions. We design and supply Programmable Logic Controllers (PLC) and Direct Digital Control (DDC) panels to streamline facility operations and integrate complex building management systems.
Ensure uninterrupted operations and power continuity. Our ATS panels are designed for seamless, automatic transitions between primary and backup power sources during utility outages.
| Bus-bar Rating | Up to 6300 A |
| Standards | Components: IS:13947 / IEC 60947. Assembly standard agreed per project |
| Testing | High-Pot, IR, FAT at DPCL facility |
| Enclosure | IP42 to IP65 (as required) |
| Finish | Powder coat / Epoxy, RAL 7035 or custom |
| Brands | Siemens, ABB, Schneider Electric |
Integrated building intelligence: CCTV, access control, BMS, PA & more.
DPCL's ELV division covers IP CCTV, biometric access control, Building Management Systems, and structured cabling, all designed, supplied, installed and commissioned as one package for commercial, institutional and industrial facilities.
HD/4K IP cameras, NVR recording and remote monitoring. Indoor/outdoor, PTZ and analytics.
Biometric, card-based and face-recognition access, with door controllers, turnstiles and boom barriers. Integration with HR systems.
BMS/BAS for HVAC, lighting, energy metering and fire alarm integration. Centralised dashboard, remote monitoring.
IP PA and EN54-16 compliant voice alarm systems for commercial buildings, hospitals, campuses and metro stations.
Master Antenna TV and IPTV distribution for hotels, hospitals and residential complexes.
Cat 6/6A copper and OM3/OM4 fibre backbone, with TIA-568/ISO 11801 certified end-to-end installations.
| CCTV Resolution | 2MP to 8MP (4K) IP cameras |
| Access Tech | RFID, Biometric, Face Rec, Mobile |
| BMS Protocol | BACnet, Modbus, LonWorks, KNX |
| Cabling | Cat 6A / Fibre, TIA-568C.2 |
| PA Standard | EN54-16 Voice Alarm compliant |
Fire-resistant and LSZH cables, specified to IS:694 and BS:7211.
DPCL supplies a comprehensive range of cables and wiring accessories, from fire-resistant and LSZH cables for critical installations to standard FR PVC cables for general wiring. We stock major brands and can supply project-specific quantities with full test certificates. Our accessories range covers conduits, trays, lugs, glands and switchgear.
Maintain circuit integrity under fire for fire alarm, emergency lighting and critical control circuits.
Low Smoke Zero Halogen cables for IT buildings, hospitals and metro stations. Minimises toxic smoke in fire conditions.
Steel wire armoured (SWA) cables for underground and direct burial applications, for power and instrumentation.
Control, instrumentation and multicore flexible cables for panel wiring and field devices.
GI / PVC conduits, perforated cable trays, ladder trays and accessories for cable management.
Copper lugs, cable glands (A2F, BW, CW types), ferrules, markers and din-rail components.
| Voltage Grade | 650V / 1100V (LT) / 11 kV (HT) |
| Standards | IS:694 / IS:1554 / BS:7211 / IEC 60502 |
| Fire Rating | BS:6387 Cat CWZ / IEC 60332 |
| BIS Certification | Ask for the certificate of the exact cable type |
| Conductor | Copper (EC grade) / Aluminium |
| Brands | Varsha Cables |
Built around the safety specifications of each project.
Our engineering team will review your requirements and respond with a tailored proposal within 24 hours.